Tutorial

Fire Extinguishers

Every salon is required to have a fire extinguisher available and in working order. sThis is to be in compliance with fire safety codes. Here is some information that salons and salon professionals should be aware of.

There are basically four different types or classes of fire extinguishers, each of which extinguishes specific types of fire. Newer fire extinguishers use a picture/labeling system to designate which types of fires they are to be used on. Older fire extinguishers are labeled with colored geometrical shapes with letter designations. Both of these types of labels are shown below with the description of the different classes of extinguishers.

Additionally, Class A and Class B fire extinguishers have a numerical rating which is based on tests conducted by Underwriter's Laboratories that are designed to determine the extinguishing potential for each size and type of extinguisher. Click on any of the topics listed below for additional information that may be helpful to know.

 

A-2

Class A Extinguishers  will put out fires in ordinary combustibles, such as wood and paper. The numerical rating for this class of fire extinguisher refers to the amount of water the fire extinguisher holds and the amount of fire it will extinguish.

A-1

 

 

B-2

Class B Extinguishers  should be used on fires involving flammable liquids, such as grease, gasoline, oil, etc. The numerical rating for this class of fire extinguisher states the approximate number of square feet of a flammable liquid fire that a non-expert person can expect to extinguish.

B-1

 

 

C-2

Class C Extinguishers  are suitable for use on electrically energized fires. This class of fire extinguishers does not have a numerical rating. The presence of the letter “C” indicates that the extinguishing agent is non-conductive.

C-1

 

 

 

Class D Extinguishers  are designed for use on flammable metals and are often specific for the type of metal in question. There is no picture designator for Class D extinguishers. These extinguishers generally have no rating nor are they given a multi-purpose rating for use on other types of fires.

d-1

 

 

 

ABC-2

Many extinguishers available today can be used on different types of fires and will be labeled with more than one designator, e.g. A-B, B-C, or A-B-C. Make sure that if you have a multi-purpose extinguisher it is properly labeled.

This is the old style of labeling indicating suitability for use on Class A, B, and C fires.

ABC-1

AB-3

This is the new style of labeling that shows this extinguisher may be used on Ordinary Combustibles, Flammable Liquids, or Electrical Equipment fires. This is the new labeling style with a diagonal red line drawn through the picture to indicate what type of fire this extinguisher is NOT suitable for. In this example, the fire extinguisher could be used on Ordinary Combustibles and Flammable Liquids fires, but not for Electrical Equipment fires.

 

 

ABC-THM

Dry Chemical extinguishers are usually rated for multiple purpose use. They contain an extinguishing agent and use a compressed, non-flammable gas as a propellant.

HAL-THM

Halon extinguishers contain a gas that interrupts the chemical reaction that takes place when fuels burn. These types of extinguishers are often used to protect valuable electrical equipment since them leave no residue to clean up. Halon extinguishers have a limited range, usually 4 to 6 feet. The initial application of Halon should be made at the base of the fire, even after the flames have been extinguished.

H2O-THM

Water   These extinguishers contain water and compressed gas and should only be used on Class A (ordinary combustibles) fires.

CO2-THM

Carbon Dioxide (CO2) extinguishers are most effective on Class B and C (liquids and electrical) fires. Since the gas disperses quickly, these extinguishers are only effective from 3 to 8 feet. The carbon dioxide is stored as a compressed liquid in the extinguisher; as it expands, it cools the surrounding air. The cooling will often cause ice to form around the “horn” where the gas is expelled from the extinguisher. Since the fire could re-ignite, continue to apply the agent even after the fire appears to be out.

 

 

How to use a Fire Extinguisher

 

Even though extinguishers come in a number of shapes and sizes, they all operate in a similar manner.  Here's an easy acronym for fire extinguisher use:


P  A  S   S   --   P ull, A im, S queeze, and S weep

 

PULL-THM

Pull the pin at the top of the extinguisher that keeps the handle from being accidentally pressed.

AIM-THM   AIM1-THM

Aim the nozzle toward the base of the fire.

SQZ-THM   SQ2-THM

Stand approximately 8 feet away from the fire and squeeze the handle to discharge the extinguisher. If you release the handle, the discharge will stop.

SW3-THM  SW4-THM

Sweep the nozzle back and forth at the base of the fire. After the fire appears to be out, watch it carefully since it may re-ignite!